Fire alarm systems
Dahua also offers fire alarm solutions that are designed to detect fires, alert people in a timely manner, and prevent the spread of fire. The main components and features of Dahua fire alarm systems include:
Smoke and Fire Detectors: Devices that detect smoke or high temperatures in a room and signal a possible fire. They can be optical, ionization, or heat detectors.
Fire Control Panels: Centralized devices that collect information from sensors and detectors, process it, and transmit alarms when a fire is detected. Fire panels can be integrated with warning and automatic fire extinguishing systems.
Alarm and Evacuation Systems: Audio systems that automatically or manually transmit voice messages and alarms to alert people to the need to evacuate.
Manual Fire Call Points (Panic Buttons): Devices that allow people to manually activate an alarm when a fire is detected.
Integration with CCTV systems: Dahua provides the ability to integrate fire alarms with CCTV, allowing you to quickly verify alarms by viewing video feeds from cameras in the area.
Automatic control of fire extinguishing systems: Fire alarm systems can be linked to water, foam or gas extinguishing systems to automatically initiate extinguishing when a fire is detected.
Dahua fire alarm solutions help ensure the safety of buildings and people by providing timely alerts and the ability to integrate with other security systems.
DH-PFS3008-8GT-L
Ports: 8x Gigabit RJ45 Transmission Speed: 10/100/1000 Mbps Switching Capacity: 16 Gbps Packet Forwarding Rate: 11.9 Mpps MAC Address
DH-PFS3005-5GT-L
Ports: 5x Gigabit RJ45 Transmission Speed: 10/100/1000 Mbps Switching Capacity: 10 Gbps Packet Forwarding Rate: 7.44 Mpps MAC Address
DH-CS4010-8ET-60
Ports: 8x Fast Ethernet PoE (10/100 Mbps) + 2x Gigabit uplink PoE Power: 60W (IEEE802.3af/at) Transmission Speed: 10/100/1000 Mbps uplink
DH-PFS3006-4ET-36
Key Specifications: Type: unmanaged PoE switch Ports: 4 × RJ-45 (10/100 Mbps, PoE) 2 × RJ-45 (10/100 Mbps, uplink) PoE standards: IEEE
DHI-HY-C136
Model: DHI-HY-C136 Type: Conventional heat detector Sensor type: Thermal sensing element Wiring: 4-wire connection Power supply: 16–28 V
ИП 212-С131/4
Device type: Fire alarm detector (optical smoke sensor) Detection principle: Photoelectric (optical) Sensitivity: 0.05 – 0.2 dB/m Power
ИП 212-С131/2
Device type: Fire alarm detector (optical smoke sensor) Detection principle: Photoelectric (optical) Sensitivity: 0.05 – 0.2 dB/m Power
DHI-HY-GB40A
Operating method Propane (C3H8) Transmission distance 70dB (A) at 1m Alarm outputs 1 valve output, 1 relay output Power supply DC12V
DHI-HY-GA40A
Operating method Methane (CH₄) Transmission distance 70dB (A) at 1m Alarm outputs 1 valve output, 1 relay output Power supply DC12V
DHI-HY-GC20B
Working method Electrochemical sensor Transmission distance 85dB (A) at 3m Power supply 3V CR123A removable Operating temperature -10°C -
DH-YJ104
Voltage: DC 24V(18V-36V) Distance: 5-100m Adjustment angle: about 15 up and 10° down Installation angle:
DHI-HY-1330
The addressable repeater panel is a companion product of fire alarm management, displaying the fire alarm information in the building. When
DHI-HY-1431
The isolator module is a product for interfacing with an addressable fire alarm control panel placed at intervals in the loop. When a short
DHI-HY-1400
Voltage: DC 24V(16V-28V) Current consumption in Standby mode: 0.15mA Current consumption in Fire mode: 0.19mA
DHI-HY-1410
Device type: Addressable heat detector Power supply: 24 V DC (via signal line) Current consumption: Monitoring ≤200 µA, Alarm ≤1 mA Sensor
DHI-HY-1410C
The addressable I/O module is a companion product of the addressable fire alarm control panel, regulating the normal operation of the
DHI-HY-1200
Convenient two-wire, non-polar connection. Reliable communication: built-in microprocessor, stable performance. Extremely low power
DHI-HY-1500
Convenient two-wire, non-polar connection. Reliable communication: built-in microprocessor, stable operation. Ultra-low consumption:
DHI-HY-1310
The addressable heat detector has integrated with non-polarity two-wire temperature sensor. It analyzes the surrounding temperature with
DHI-HY-1301
Addressable non-polar smoke detector. When the concentration reaches the alarm threshold, the addressable fire control panel will confirm
DHI-HY-1022
· The system loop line adopts two-wire and polarity-free communication power supply technology, without external power supply. · Ultra-long
DH-C2K-P
Sensor: 2 MP (1920×1080) CMOS Video: Full HD 1080p Viewing angle: approx. 100–110° Night vision: IR LEDs up to ~10 m Connectivity: Wi-Fi
DHI-HY-JST3-UZ (односторонее)
Device type: One-way signaling / audio system Technology: Two-wire, polarity-free Operating voltage: DC 16V – 28V Current consumption: ≤
DHI-HY-JST2-UZ (двухсторонее)
Device type: Two-way signaling / audio system Technology: Two-wire, polarity-free Operating voltage: DC 16V – 28V Current consumption: ≤